This paper presents the results of an experimental and numerical investigation of the cyclic behaviour of steel T-stub connections tied to a rigid base made of S355 JR steel grade, subjected to the ECCS cyclic loading protocol. Twenty tests were conducted on two sets of specimens, with varying flange thickness and length, and accounting for the presence of finger shims. Finite element models were calibrated against the experimental results and used to investigate the influence of bolt shank orientation with respect to the rigid base on the ultimate connection capacity and the flexural demand on the bolt. The experimental results showed that T-stub connections with thin plates experienced the flange fracture at the section adjacent to the stem with an associated cumulative plastic demand in the range 500–900. The presence of finger shims has a limited effect on connection performance, with a discernible influence only when failure is governed by bolt rupture. The models accurately the cyclic behaviour of the investigated specimens, and the numerical results underline that bolt shank orientation can significantly affect connection response at large displacements. Configurations in which the bolt head is in contact with the flange exhibit the greatest increase in resistance.

Cyclic response of S355JR T-stub connections tied-to-rigid base subjected to ECCS protocol

Tartaglia R.
Funding Acquisition
;
2026-01-01

Abstract

This paper presents the results of an experimental and numerical investigation of the cyclic behaviour of steel T-stub connections tied to a rigid base made of S355 JR steel grade, subjected to the ECCS cyclic loading protocol. Twenty tests were conducted on two sets of specimens, with varying flange thickness and length, and accounting for the presence of finger shims. Finite element models were calibrated against the experimental results and used to investigate the influence of bolt shank orientation with respect to the rigid base on the ultimate connection capacity and the flexural demand on the bolt. The experimental results showed that T-stub connections with thin plates experienced the flange fracture at the section adjacent to the stem with an associated cumulative plastic demand in the range 500–900. The presence of finger shims has a limited effect on connection performance, with a discernible influence only when failure is governed by bolt rupture. The models accurately the cyclic behaviour of the investigated specimens, and the numerical results underline that bolt shank orientation can significantly affect connection response at large displacements. Configurations in which the bolt head is in contact with the flange exhibit the greatest increase in resistance.
2026
Cumulative damage
Experimental cyclic tests
Finger shims
Finite element analysis
Parametric analyses
T-stub
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12070/77870
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact