The paper presents the design and the construction of a real mock-up two-story exhibition building having a load bearing cold-formed steel (CFS) structure, where the lateral force resisting system (LFRS) is represented by an innovative hybrid wall made of CFS studs and tracks laterally braced by ultra-high strength (UHS) steel pretensioned diagonal bars. The hybrid CFS wall represents the result of the Italian research project, named ECCELSA, aimed to develop a CFS LFRS wall capable to be used where high resistance capacity is required, as in the case of medium-to-high seismic areas or medium-rise buildings. From the design and construction point of view, the real mock-up building presented in this paper appears to best satisfy the high safety, durability and eco-efficiency standards required by the building construction market. In order to verify the effectiveness of the design procedure adopted, a refined numerical model was developed and validated against the experimental results obtained during the research project. The results of non-linear static analyses highlighted a structural overstrength and revealed the building ductility, mainly due to the hardening and ultimate elongation of the UHS bars, which had not been accounted for during the design phase.

Seismic-resistant CFS walls braced with pre-tensioned UHS steel bars: Design and construction of a building mockup

Tartaglia, Roberto;
2025-01-01

Abstract

The paper presents the design and the construction of a real mock-up two-story exhibition building having a load bearing cold-formed steel (CFS) structure, where the lateral force resisting system (LFRS) is represented by an innovative hybrid wall made of CFS studs and tracks laterally braced by ultra-high strength (UHS) steel pretensioned diagonal bars. The hybrid CFS wall represents the result of the Italian research project, named ECCELSA, aimed to develop a CFS LFRS wall capable to be used where high resistance capacity is required, as in the case of medium-to-high seismic areas or medium-rise buildings. From the design and construction point of view, the real mock-up building presented in this paper appears to best satisfy the high safety, durability and eco-efficiency standards required by the building construction market. In order to verify the effectiveness of the design procedure adopted, a refined numerical model was developed and validated against the experimental results obtained during the research project. The results of non-linear static analyses highlighted a structural overstrength and revealed the building ductility, mainly due to the hardening and ultimate elongation of the UHS bars, which had not been accounted for during the design phase.
2025
Case study
Cold-formed steel
Numerical modelling
Seismic design
UHS steel bracing
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12070/70010
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact