Industrial single-storey buildings are the most diffuse typology of steel construction located in Italy. Most of these existing buildings were erected prior to the enforcement of adequate seismic provisions; hence, crucial attention is paid nowadays to the design of low-impact retrofit interventions which can restore a proper structural performance without interrupting productive activities. Within this framework, an existing industrial single-storey steel building located in Nusco (Italy) is selected in this paper as a case-study. The structure, which features moment resisting (MR) truss frames in both directions, is highly deformable and presents undersized MR bolted connections. Structural performance of the case-study was assessed by means of both global and local refined numerical analyses. As expected, the inadequate performance of connections, which fail due to brittle mechanisms, detrimentally affects the global response of the structure both in terms of lateral stiffness and resistance. This effect was accounted for in global analyses by means of properly calibrated non-linear links. Thus, both local and global retrofit interventions were designed and numerically investigated. Namely, lower chord connections were strengthened by means of rib stiffeners and additional rows of M20 10.9 bolts, whereas concentrically braced frames (CBFs) were placed on both directions' facades. Designed interventions proved to be effective for the full structural retrofitting against both seismic and wind actions without limiting building accessibility.

Seismic Retrofitting of Existing Industrial Steel Buildings: A Case-Study

Tartaglia, Roberto;
2022-01-01

Abstract

Industrial single-storey buildings are the most diffuse typology of steel construction located in Italy. Most of these existing buildings were erected prior to the enforcement of adequate seismic provisions; hence, crucial attention is paid nowadays to the design of low-impact retrofit interventions which can restore a proper structural performance without interrupting productive activities. Within this framework, an existing industrial single-storey steel building located in Nusco (Italy) is selected in this paper as a case-study. The structure, which features moment resisting (MR) truss frames in both directions, is highly deformable and presents undersized MR bolted connections. Structural performance of the case-study was assessed by means of both global and local refined numerical analyses. As expected, the inadequate performance of connections, which fail due to brittle mechanisms, detrimentally affects the global response of the structure both in terms of lateral stiffness and resistance. This effect was accounted for in global analyses by means of properly calibrated non-linear links. Thus, both local and global retrofit interventions were designed and numerically investigated. Namely, lower chord connections were strengthened by means of rib stiffeners and additional rows of M20 10.9 bolts, whereas concentrically braced frames (CBFs) were placed on both directions' facades. Designed interventions proved to be effective for the full structural retrofitting against both seismic and wind actions without limiting building accessibility.
2022
existing structures
finite element analyses
seismic retrofitting
steel constructions
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12070/62765
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 17
social impact