In this work, the numerical and experimental analysis on the use of thinned fiber Bragg gratings as refractive index sensors have been carried out. Wet chemical etching in a buffered hydrofluoric acid solution was used for sensor fabrication. Experimental characterization for an almost full etched cladding sensor is presented demonstrating good agreement with numerical results and resolutions of approximate to 10(-5) and approximate to 10(-4) for outer refractive index around 1.45 and 1.333, respectively.

In this work, the numerical and experimental analysis on the use of thinned fiber Bragg gratings as refractive index sensors have been carried out. Wet chemical etching in a buffered hydrofluoric acid solution was used for sensor fabrication. Experimental characterization for an almost full etched cladding sensor is presented demonstrating good agreement with numerical results and resolutions of ≈10-5 and ≈10-4 for outer refractive index around 1.45 and 1.333, respectively.

Thinned Fiber Bragg Gratings as High Sensitivity Refractive Index Sensor

IADICICCO A;CUSANO A
;
CUTOLO A;
2004-01-01

Abstract

In this work, the numerical and experimental analysis on the use of thinned fiber Bragg gratings as refractive index sensors have been carried out. Wet chemical etching in a buffered hydrofluoric acid solution was used for sensor fabrication. Experimental characterization for an almost full etched cladding sensor is presented demonstrating good agreement with numerical results and resolutions of ≈10-5 and ≈10-4 for outer refractive index around 1.45 and 1.333, respectively.
2004
In this work, the numerical and experimental analysis on the use of thinned fiber Bragg gratings as refractive index sensors have been carried out. Wet chemical etching in a buffered hydrofluoric acid solution was used for sensor fabrication. Experimental characterization for an almost full etched cladding sensor is presented demonstrating good agreement with numerical results and resolutions of approximate to 10(-5) and approximate to 10(-4) for outer refractive index around 1.45 and 1.333, respectively.
File in questo prodotto:
File Dimensione Formato  
Thinned fiber Bragg gratings as high sensitivity refractive index sensor.pdf

non disponibili

Licenza: Non specificato
Dimensione 133.1 kB
Formato Adobe PDF
133.1 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12070/600
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 352
  • ???jsp.display-item.citation.isi??? 279
social impact