The paper is focused on the evaluation of how the climate changes can influence the performance of buildings designed to be nearly zero energy (nZEB) and on the evaluation of the resilience in term of energy balance. A real case study is used; it is named BNZEB, a single-storey dwelling built in Benevento (South Italy, Mediterranean climate). With five-years monitored meteorological data, both a short-term and medium-term analysis is developed; the first one consists in the evaluation of the energy behavior compared to the first operating year. Then, the energy performance is evaluated considering the medium-term climate projections generated using the CCWorldWeatherGen tool. This analysis, with reference to the case study, suggests to designers and researchers that, in a typical Mediterranean climate, the reduction of the heating demand could compensate the increment in the cooling request. In the worst climatic scenario, the net primary energy could change from 25.4 kWh/m2 year (first year of life, 2017) to 19.5 kWh/m2 year (projection to 2050) with a rate of self-consumption of 85% (80% for 2017). However, a critical point is the operating period of the cooling system. Indeed, an indoor overheating problem could occur during the spring with operative temperature higher than 30 °C; this indicates that in future, the occupants will require higher number of operating hours with most frequent switch off. This could change the results of the energy balance, reducing, for instance, the imbalance between production and consumption that currently occurs in the intermediate periods.

Resilience to the climate change of nearly zero energy-building designed according to the EPBD recast: Monitoring, calibrated energy models and perspective simulations of a Mediterranean nZEB living lab

Rosa Francesca De Masi
;
Antonio Gigante;Giuseppe Peter Vanoli
2022-01-01

Abstract

The paper is focused on the evaluation of how the climate changes can influence the performance of buildings designed to be nearly zero energy (nZEB) and on the evaluation of the resilience in term of energy balance. A real case study is used; it is named BNZEB, a single-storey dwelling built in Benevento (South Italy, Mediterranean climate). With five-years monitored meteorological data, both a short-term and medium-term analysis is developed; the first one consists in the evaluation of the energy behavior compared to the first operating year. Then, the energy performance is evaluated considering the medium-term climate projections generated using the CCWorldWeatherGen tool. This analysis, with reference to the case study, suggests to designers and researchers that, in a typical Mediterranean climate, the reduction of the heating demand could compensate the increment in the cooling request. In the worst climatic scenario, the net primary energy could change from 25.4 kWh/m2 year (first year of life, 2017) to 19.5 kWh/m2 year (projection to 2050) with a rate of self-consumption of 85% (80% for 2017). However, a critical point is the operating period of the cooling system. Indeed, an indoor overheating problem could occur during the spring with operative temperature higher than 30 °C; this indicates that in future, the occupants will require higher number of operating hours with most frequent switch off. This could change the results of the energy balance, reducing, for instance, the imbalance between production and consumption that currently occurs in the intermediate periods.
2022
Building resilience, Climate change, Mediterranean climate, nZEB, Real case study
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12070/55399
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? ND
social impact