This work is focused on the room temperature sensitivities and response times analysis against aromatic volatile organic compounds of both silica optical fiber and quartz crystal microbalance sensors, coated by single-walled carbon nanotubes (SWCNTs) Langmuir-Blodgett multilayers; as highly sensitive nanomaterials. The fabricated samples have been characterized by means of X-ray diffraction, high-resolution transmission electron microscopy and scanning electron microscopy, silica optical fiber, and quartz crystal microbalance transducers have been simultaneously exposed at room temperature to toluene and xylene individual vapors in the ppm range. For each transducer type, a time division multiplexing approach has been exploited, enabling the simultaneous interrogation of up to 8 optical and 6 acoustic probes, respectively. The results obtained indicate that both optical and acoustic sensors provide very high reproducibility and sensitivity either towards toluene or xylene, with a resolution of few hundreds of ppb. Furthermore, sensitivities and response times turned out to be dependent on the particular analytes; used for the vapors testing. Both transducer types demonstrate a similar response time, while with regard the recovery time, the optical detection seems to be significantly faster than the electrical counterpart. The effect of the SWCNTs monolayers number on sensors sensitivity and response time has also been investigated, demonstrating the possibility to enhance the performances of the proposed transducers by tailoring the geometric properties of the sensitive nanomaterial.

Carbon nanotubes coated acoustic and optical VOCs sensors: Towards the tailoring of the sensing performances

Consales Marco;Cutolo Antonello;Cusano A
2007-01-01

Abstract

This work is focused on the room temperature sensitivities and response times analysis against aromatic volatile organic compounds of both silica optical fiber and quartz crystal microbalance sensors, coated by single-walled carbon nanotubes (SWCNTs) Langmuir-Blodgett multilayers; as highly sensitive nanomaterials. The fabricated samples have been characterized by means of X-ray diffraction, high-resolution transmission electron microscopy and scanning electron microscopy, silica optical fiber, and quartz crystal microbalance transducers have been simultaneously exposed at room temperature to toluene and xylene individual vapors in the ppm range. For each transducer type, a time division multiplexing approach has been exploited, enabling the simultaneous interrogation of up to 8 optical and 6 acoustic probes, respectively. The results obtained indicate that both optical and acoustic sensors provide very high reproducibility and sensitivity either towards toluene or xylene, with a resolution of few hundreds of ppb. Furthermore, sensitivities and response times turned out to be dependent on the particular analytes; used for the vapors testing. Both transducer types demonstrate a similar response time, while with regard the recovery time, the optical detection seems to be significantly faster than the electrical counterpart. The effect of the SWCNTs monolayers number on sensors sensitivity and response time has also been investigated, demonstrating the possibility to enhance the performances of the proposed transducers by tailoring the geometric properties of the sensitive nanomaterial.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12070/557
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 22
social impact