This paper assesses the reliability of code-compliant linear and nonlinear dynamic analyses for irregular buildings with base isolation system (BIS). Comprehensive analyses are carried out for a case study comprising a large reinforced concrete multi-storey framed hospital with 327 high-damping rubber bearings. Spectral and time history (linear and nonlinear) analyses were performed on the three-dimensional (3D) finite element model (FEM) of the structure; simplified analyses were also conducted on single-degree-of-freedom (SDOF) systems. It is found that, at damageability limit state, the values of maximum interstorey drifts (d/h) computed with spectral analyses on the three-dimensional FEM range between 1/6 and 1/10 of the code limit (d/h = 0.33%); thus more stringent code limits should be required for buildings with BISs. The maximum floor acceleration is reduced by about 70% with respect to the ground acceleration (free field site); the acceleration profile is uniform along the height of the multi-storey frame. Threshold values of floor accelerations to assess the seismic performance of equipments in buildings with BIS are lacking. At ultimate limit state (ULS), spectral analyses provide values of actions and deformations that are less conservative than those derived through time history analyses. To perform reliable dynamic analyses of base isolated buildings it is crucial to select natural earthquake ground motions compliant with the fundamental period of vibration of the structural system. Nevertheless, it is not straightforward to select adequate natural strong motions in the catalogues available world-wide; buildings incorporating BISs possess periods of vibration which are generally higher than 2.0 s. As a result, distant and high-magnitude earthquakes are effective for base isolated buildings; nevertheless, such earthquakes are scarce in the seismic databases. The outcomes of the present study also demonstrate that simplified linear analyses tend to provide estimates of the response quantities, displacements of base isolators and base shear of the superstructure, which can be reliably employed at preliminary design stage. Spectral analysis results of the 3D model tend to match those of the SDOF systems, even for irregular superstructure, provided that modal mass participating ratios are greater than 85-90%. The results of spectral analyses on both SDOF and three-dimensional FEM envelope the outcomes of linear time histories

Seismic Response Analysis of An Irregular Base Isolated Building

Di Sarno L;
2011-01-01

Abstract

This paper assesses the reliability of code-compliant linear and nonlinear dynamic analyses for irregular buildings with base isolation system (BIS). Comprehensive analyses are carried out for a case study comprising a large reinforced concrete multi-storey framed hospital with 327 high-damping rubber bearings. Spectral and time history (linear and nonlinear) analyses were performed on the three-dimensional (3D) finite element model (FEM) of the structure; simplified analyses were also conducted on single-degree-of-freedom (SDOF) systems. It is found that, at damageability limit state, the values of maximum interstorey drifts (d/h) computed with spectral analyses on the three-dimensional FEM range between 1/6 and 1/10 of the code limit (d/h = 0.33%); thus more stringent code limits should be required for buildings with BISs. The maximum floor acceleration is reduced by about 70% with respect to the ground acceleration (free field site); the acceleration profile is uniform along the height of the multi-storey frame. Threshold values of floor accelerations to assess the seismic performance of equipments in buildings with BIS are lacking. At ultimate limit state (ULS), spectral analyses provide values of actions and deformations that are less conservative than those derived through time history analyses. To perform reliable dynamic analyses of base isolated buildings it is crucial to select natural earthquake ground motions compliant with the fundamental period of vibration of the structural system. Nevertheless, it is not straightforward to select adequate natural strong motions in the catalogues available world-wide; buildings incorporating BISs possess periods of vibration which are generally higher than 2.0 s. As a result, distant and high-magnitude earthquakes are effective for base isolated buildings; nevertheless, such earthquakes are scarce in the seismic databases. The outcomes of the present study also demonstrate that simplified linear analyses tend to provide estimates of the response quantities, displacements of base isolators and base shear of the superstructure, which can be reliably employed at preliminary design stage. Spectral analysis results of the 3D model tend to match those of the SDOF systems, even for irregular superstructure, provided that modal mass participating ratios are greater than 85-90%. The results of spectral analyses on both SDOF and three-dimensional FEM envelope the outcomes of linear time histories
2011
Hospital; Seismic analysis; Base isolation
File in questo prodotto:
File Dimensione Formato  
Bullettin of Eartquake Engineering 2011.pdf

non disponibili

Licenza: Non specificato
Dimensione 8.1 MB
Formato Adobe PDF
8.1 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12070/2813
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 44
  • ???jsp.display-item.citation.isi??? 32
social impact